Products

Ignition Systems

Electronic Ignition Systems

Electronic ignition systems are primarily used in gas heating and cooking applications for ignition and flame monitoring purposes and are compliant with DIN 3446 and DIN EN 60 335-1 Standards.

Special Features Include:

  • Repetitive spark ignition systems
  • Designed for one to six ignition points
  • Low power consumption
  • Longevity guaranteed by semiconductors
  • Equipped with fastons for mains and high voltage connections  

Type

Supply Voltage

Number of Outputs

Spark Frequency

Max. Temperature

E 3702/61

1.5 V

DC 2

4 – 16 Hz

70 °C

E 3707/24

230 V

AC 2

4 Hz

100 °C

E 3712/12

12 V

DC 2

2 – 16 Hz

70 °C

E 3713

230 V

AC 1

50 Hz

70 °C

E 3713/1

230 V

AC 1

5 Hz

110 °C

E 3748/2

115/230 V

AC 2

2 – 16 Hz

125 °C

E 3748/4

115/230 V

AC 4

2 – 16 Hz

125 °C

E 3748/6

115/230 V

AC 6

2 – 16 Hz

125 °C

Ignition Transformers

Eichhoff's Ignition Transformers, compliant with DIN 3446 and DIN EN 60 335-1 standards, ensure reliable ignition performance and are ideal for gas and oil burner applications.  These transformers are meticulously designed and tested to meet industry standards, providing safe and efficient ignition solutions for various industrial needs.  Special features include:

  • Circuit board assembly for enhanced reliability
  • Compact dimensions ideal for space-constrained installations
  • Designed for one or two ignition points
  • Primary connections via solder pins for secure PCB mounting
  • Secondary connections feature fastons (2.8 x 0.8 mm) for convenience
  • Rigorous individual quality testing ensures consistent performance
  • Self-extinguishing potting and housing materials enhance safety and durability

Type

Primary Connection

Secondary Output 1

Secondary Output 2

Max. Temperature

E 3746/1xx

Solder pins

Fastons

Fastons

85 °C

E 3746/2xx

Solder pins

Solder pins

Solder pins

85 °C

E 3746/300

Solder pins

Solder pins

Fastons

85 °C

High Frequency Ignition Systems

According to DIN 3446, DIN EN 60 335-1

Special features:

  • High frequency ignition system
  • Safe and stable ignition
  • Quality is based on individual testing

Applications: gas and oil burners

Type

Supply Voltage

Output Voltage / Current

Number of Outputs

E 4718/25

230 V

AC ≥ 20 kV / 40 mA

1

E 4718/30

120 V

AC ≥ 20 kV / 40 mA

1

E 4718/55

230 V

AC ≥ 20 kV / 40 mA

1

Flat Transformers

Flat transformers are primarily used for providing a fail-safe power supply and continuous function of electrical devices. They are commonly used in various applications such as:

  • Industrial machinery and equipment
  • Control panels and distribution boards
  • Power supply units
  • Lighting fixtures
  • Heating and ventilation systems
  • Renewable energy systems
  • Medical equipment
  • Telecommunication devices

Flat Transformer UI 30

  • Primary voltage: 115 – 250 Vac
  • Secondary voltage: 3 to 24V
  • Output power: Up to 10 VA
  • Further versions available upon request, including primary and secondary voltages, and pin configurations
  • Features a two-chamber bobbin design
  • Safety class II compliant
  • Protective system rated IP00
  • Approved to EN 61558 standards
  • Offers permanent corrosion protection, high insulation value, and maximum electrical reliability
  • Double input voltage option for series or parallel connection
  • Available with double output voltage for series or parallel connection

Flat Transformer UI 39

  • Primary voltage: 115 – 250 Vac
  • Secondary voltage: 3 to 24V
  • Output power: Up to 32 VA
  • Further versions available upon request, including primary and secondary voltages, and pin configurations
  • Features a two-chamber bobbin design
  • Safety class II compliant
  • Protective system rated IP00
  • Approved to EN 61558 standards
  • Offers permanent corrosion protection, high insulation value, and maximum electrical reliability
  • Double input voltage option for series or parallel connection
  • Available with double output voltage for series or parallel connection

Safety Transformers

Eichhoff Safety Transformers are primarily used to ensure a fail-safe power supply and continuous function of electrical devices. They are designed to provide reliable electrical isolation and protection against electrical hazards in various applications.  These transformers play a crucial role in maintaining the safety and integrity of electrical circuits and devices by isolating them from potentially harmful voltages and ensuring stable and reliable operation.

Applications include:

  • Industrial machinery and equipment
  • Control systems and panels
  • HVAC systems
  • Lighting fixtures
  • Medical equipment
  • Audiovisual equipment
  • Power distribution systems
  • Test and measurement instruments
  • Automation systems
  • Security and surveillance systems

Safety Transformer EE 20

  • Primary voltage 115 – 250 Vac
  • Secondary voltage from 3V to 24V
  • Output power up to 0.6 VA
  • Further versions, primary and secondary voltages and pin configurations on request
  • Two chamber bobbin
  • Safety class II
  • Protective system IP00
  • Approved to EN 61558
  • Permanent corrosion protection, high insulation value and maximum electrical reliability
  • Also with double output voltage for series or parallel connection

Safety Transformers EI 30

  • Primary voltage 110 – 250 Vac
  • Secondary voltage from 3 to 24V
  • Output power up to 4.8 VA
  • VDE approved
  • UL approved
  • Further versions, primary and secondary voltages and pin configurations on request
  • Two chamber bobbin
  • Safety class II
  • Protective system IP00
  • Approved to EN 61558
  • Permanent corrosion protection, high insulation value and maximum electrical reliability
  • Double input voltage for series or parallel connection
  • Also with double output voltage for series or parallel connection

Safety Transformer EI 38

  • Primary voltage 110 – 250 Vac
  • Secondary voltage from 3 to 24V
  • Output power up to 6 VA
  • VDE approved
  • Further versions, primary and secondary voltages and pin configurations on request
  • Two chamber bobbin
  • Safety class II
  • Protective system IP00
  • Approved to EN 61558
  • Permanent corrosion protection, high insulation value and maximum electrical reliability
  • Double input voltage for series or parallel connection
  • Also with double output voltage for series or parallel connection

Safety Transformer EI 42

  • Primary voltage 110 – 250 Vac
  • Secondary voltage from 3 to 24V
  • Output power up to 8.5 VA
  • VDE approved
  • Further versions, primary and secondary voltages and pin configurations on request
  • Two chamber bobbin
  • Safety class II
  • Protective system IP00
  • Approved to EN 61558
  • Permanent corrosion protection, high insulation value and maximum electrical reliability
  • Double input voltage for series or parallel connection
  • Also with double output voltage for series or parallel connection

Safety Transformer EI 48

  • Primary voltage 115 – 250 Vac
  • Secondary voltage from 3 to 24V
  • Output power up to 13 VA
  • Further versions, primary and secondary voltages and pin configurations on request
  • Two chamber bobbin
  • Safety class II
  • Protective system IP00
  • Approved to EN 61558
  • Permanent corrosion protection, high insulation value and maximum electrical reliability
  • Double input voltage for series or parallel connection
  • Also with double output voltage for series or parallel connection

Safety Transformer EI 54

  • Primary voltage 115 – 250 Vac
  • Secondary voltage from 3 to 24V
  • Output power up to 20.5 VA
  • Further versions, primary and secondary voltages and pin configurations on request
  • Two chamber bobbin
  • Safety class II
  • Protective system IP00
  • Approved to EN 61558
  • Permanent corrosion protection, high insulation value and maximum electrical reliability
  • Double input voltage for series or parallel connection
  • Also with double output voltage for series or parallel connection

Safety Transformers EI 60

  • Primary voltage 110 – 250 Vac
  • Secondary voltage from 3 to 24V
  • Output power up to 30 VA
  • Further versions, primary and secondary voltages and pin configurations on request
  • Two chamber bobbin
  • Safety class II
  • Protective system IP00
  • Approved to EN 61558
  • Permanent corrosion protection, high insulation value and maximum electrical reliability
  • Double input voltage for series or parallel connection
  • Also with double output voltage for series or parallel connection

Safety Transformers EI 66

  • Primary voltage 115 – 250 Vac
  • Secondary voltage from 3 to 24V
  • Output power up to 63 VA
  • Further versions, primary and secondary voltages and pin configurations on request
  • Two chamber bobbin
  • Safety class II
  • Protective system IP00
  • Approved to EN 61558
  • Permanent corrosion protection, high insulation value and maximum electrical reliability
  • Double input voltage for series or parallel connection
  • Also with double output voltage for series or parallel connection

Safety Transformer EI 84

  • Primary voltage 115 – 250 Vac
  • Secondary voltage from 3 to 24V
  • Output power up to 100 VA
  • Further versions, primary and secondary voltages and pin configurations on request
  • Two chamber bobbin
  • Safety class II
  • Protective system IP00
  • Approved to EN 61558
  • Permanent corrosion protection, high insulation value and maximum electrical reliability
  • Double input voltage for series or parallel connection
  • Also with double output voltage for series or parallel connection

English | Deutsch | Magyar

Eichhoff Elektro Kft. - 2600 Vác, Deákvári Fasor 12 - Hungary
Tel: 0036 27 317-083 | Tel: 0036 27 317-084 | Fax: 0036 27 511-187

Web Site Design and Hosting by Saco Design | Powered by Site Avenger CMS