Eichhoff News

Safety Transformer EE 20

  • Primary voltage 115 – 250 Vac
  • Secondary voltage from 3V to 24V
  • Output power up to 0.6 VA
  • Further versions, primary and secondary voltages and pin configurations on request
  • Two chamber bobbin
  • Safety class II
  • Protective system IP00
  • Approved to EN 61558
  • Permanent corrosion protection, high insulation value and maximum electrical reliability
  • Also with double output voltage for series or parallel connection

Safety Transformer EI 38

  • Primary voltage 110 – 250 Vac
  • Secondary voltage from 3 to 24V
  • Output power up to 6 VA
  • VDE approved
  • Further versions, primary and secondary voltages and pin configurations on request
  • Two chamber bobbin
  • Safety class II
  • Protective system IP00
  • Approved to EN 61558
  • Permanent corrosion protection, high insulation value and maximum electrical reliability
  • Double input voltage for series or parallel connection
  • Also with double output voltage for series or parallel connection

Safety Transformer EI 42

  • Primary voltage 110 – 250 Vac
  • Secondary voltage from 3 to 24V
  • Output power up to 8.5 VA
  • VDE approved
  • Further versions, primary and secondary voltages and pin configurations on request
  • Two chamber bobbin
  • Safety class II
  • Protective system IP00
  • Approved to EN 61558
  • Permanent corrosion protection, high insulation value and maximum electrical reliability
  • Double input voltage for series or parallel connection
  • Also with double output voltage for series or parallel connection

Safety Transformer EI 48

  • Primary voltage 115 – 250 Vac
  • Secondary voltage from 3 to 24V
  • Output power up to 13 VA
  • Further versions, primary and secondary voltages and pin configurations on request
  • Two chamber bobbin
  • Safety class II
  • Protective system IP00
  • Approved to EN 61558
  • Permanent corrosion protection, high insulation value and maximum electrical reliability
  • Double input voltage for series or parallel connection
  • Also with double output voltage for series or parallel connection

Safety Transformer EI 54

  • Primary voltage 115 – 250 Vac
  • Secondary voltage from 3 to 24V
  • Output power up to 20.5 VA
  • Further versions, primary and secondary voltages and pin configurations on request
  • Two chamber bobbin
  • Safety class II
  • Protective system IP00
  • Approved to EN 61558
  • Permanent corrosion protection, high insulation value and maximum electrical reliability
  • Double input voltage for series or parallel connection
  • Also with double output voltage for series or parallel connection

Safety Transformer EI 84

  • Primary voltage 115 – 250 Vac
  • Secondary voltage from 3 to 24V
  • Output power up to 100 VA
  • Further versions, primary and secondary voltages and pin configurations on request
  • Two chamber bobbin
  • Safety class II
  • Protective system IP00
  • Approved to EN 61558
  • Permanent corrosion protection, high insulation value and maximum electrical reliability
  • Double input voltage for series or parallel connection
  • Also with double output voltage for series or parallel connection

Safety Transformers EI 30

  • Primary voltage 110 – 250 Vac
  • Secondary voltage from 3 to 24V
  • Output power up to 4.8 VA
  • VDE approved
  • UL approved
  • Further versions, primary and secondary voltages and pin configurations on request
  • Two chamber bobbin
  • Safety class II
  • Protective system IP00
  • Approved to EN 61558
  • Permanent corrosion protection, high insulation value and maximum electrical reliability
  • Double input voltage for series or parallel connection
  • Also with double output voltage for series or parallel connection

Safety Transformers EI 60

  • Primary voltage 110 – 250 Vac
  • Secondary voltage from 3 to 24V
  • Output power up to 30 VA
  • Further versions, primary and secondary voltages and pin configurations on request
  • Two chamber bobbin
  • Safety class II
  • Protective system IP00
  • Approved to EN 61558
  • Permanent corrosion protection, high insulation value and maximum electrical reliability
  • Double input voltage for series or parallel connection
  • Also with double output voltage for series or parallel connection

Safety Transformers EI 66

  • Primary voltage 115 – 250 Vac
  • Secondary voltage from 3 to 24V
  • Output power up to 63 VA
  • Further versions, primary and secondary voltages and pin configurations on request
  • Two chamber bobbin
  • Safety class II
  • Protective system IP00
  • Approved to EN 61558
  • Permanent corrosion protection, high insulation value and maximum electrical reliability
  • Double input voltage for series or parallel connection
  • Also with double output voltage for series or parallel connection